Menu Driven
Commands
Simply
select the functions desired. No memorization or operation manual
required.
Self-guiding
Prompts
Clear
and concise instructions are prompted across the large graphic LCD
display in every measurement
Help Key Provides
Explanation of Key Functions
Detailed
explanations are available for all measurement functions along with
answers to frequently asked questions
Quick Calibration
It
takes seconds to calibrate using the quick calibration function.
Standard Calibration is also available.
Auto-Function
Auto-function
allows the user to measure density, dot gain and ink trap, interchangeably.
Large Graphic
LCD Display
The
easy to read graphic LCD display allows the user to determine the
precise configuration desired, including right or left handed view,
two or three decimal precision and display options.
Printer and
Computer Interface
The
configurable RS-232C serial interface is capable of linking the
densitometer to a computer or to the Ihara PR-95 printer.
Security User
Code (optional)
As
an option to safeguard your investment, the densitometer may be
set to operate only with the correct user code.
Pricing
| Measurement
Functions |
Power
Supply
|
| Density |
Ni-Cad
(4.8V), 800mAh |
| Dot
Area (Murray-Davies or Yule-Nielsen) |
Recharge
Time |
| Dot
Gain |
Approximately
1.5 Hours |
| Ink
Trap (Brunner, Preucil or Newsprint) |
Measurements
Per Charge |
| Print
Contrast |
Approximately
4,000 (internal testing) |
| Hue
Error |
Warm
Up Time
|
| Grayness |
None |
| Saturation |
Measuring
Time |
| Cast |
Approximately
1 second |
| Brightness |
Operating
Temperature Range |
| Dot
Analysis (Print Characteristic Curve) |
41ºF
~ 104ºF (5ºC ~ 40ºC) |
| Auto-Function |
Polarization
Filter |
| Filter
Response |
(optional) |
| Status
T |
Security
User Code |
| Status
E |
(optional) |
| Status
A |
Dimensions |
| Measuring
Geometry |
2
3/4"W x 2"H x 8 1/4"L |
| 0º/45º
(ANSI PH2.17, ISO 5/4, DIN 16536) |
(72mm
x 50mm x 210mm) |
| Measuring
Range |
Weight |
| Density
0.00D-2.50D |
1.2
lbs (with batteries) |
| Dot
Area 0%-100% |
(530g) |
| Repeatability |
Computer
Output |
| ±
1.01D or 1% |
Configurable
RS-232C Serial Interface |
| Accuracy |
Accessories |
| ±
0.02D or 2% |
Operation
Manual |
| Light
Source |
Calibration
Standard |
| Halogen
Lamp, Approximately 2856ºK |
AC
Adapter (9V, 500mA, center-negative) |
| Aperture
Diameter |
Carrying
Case |
| 3.0mm
(1.7mm optional) |
Serial
Interface Cable (optional) |
| Detector |
Ihara
PR-95 Printer (optional) |
| GaAsP
Photodiode |
Software
(optional) |
| Display
|
Cable
Harness (optional) |
| 128
x 64 Dot Graphic LCD |
|